Field

Hach

AS950 Portable Sampler

Sampling has never been this easy!

The Hach AS950 Portable Sampler is a field portable sampler ideal for environmental, stormwater and/or industrial sampling.

Complete with a large, full-colour display, the Hach AS950 Portable Sampler can be programmed without the need for a field laptop.  It offers USB upload & download capabilities, and the ability to copy programs between samplers.

The Hach AS950 portable sampler is available in three base sizes:

1.  Compact for smaller manhole applications;

2. Standard for a majority of applications;

3.  Large to allow for large bottle composite sampling.

For stormwater sampling, the Hach AS950 portable sampler provides the ability to initiate up to two different programs based on user-defined conditions, such as rainfall or pH thresholds.

For industrial sampling, the Hach AS950 portable sampler is available with a non-contact liquid detect to prevent cross contamination of samples.

The Hach AS950 can be further programmed to collect varying sample sizes, collect samples at user-specified time intervals (i.e., time-weighted) or flow volume increments (i.e., flow-weighted), or collect samples over an entire run-off event as determined by a rain or flow sensor.  Sample tubing can be replaced quickly without tools.

Various models are available.

Please discuss with Aqualab before ordering.

FEATURES
Easiest and most intuitive operation

The large full colour display and intuitive programming give you access to all your programmable criteria on a single screen – eliminating scrolling through menus and supporting error-free operation.

Most convenient data transfer and programming available

The AS950 is the only sampler that utilises a USB drive to upload and download data and copy programs from one sampler to another.

Confidence in your sampling process

The program status screen instantly communicates alarms, missed samples and program progress for quick and easy troubleshooting.

Field convertible for compact or discrete sampling

Weighing only 12.7 kg, the AS950 portable sampler is designed for accuracy and convenience. Quickly switch between composite and discrete sampling in the field. Configurable for single or multiple bottle applications, it is specifically designed for use in 18-inch manholes.

Easy maintenance at low cost

Spring-mounted rollers provide long tubing life keeping maintenance costs low. The desiccant and pump tubing can easily be accessed; the replacement is possible without any tools. The rugged see-through pump cover is made for a quick visual inspection.

Specs
Alarm Configurable alarms that show on status screen and are recorded in diagnostics alarm logs. Alarms can be set for system diagnostics and logging such as program end, sample complete, missed samples and full bottle. Channel alarms are setpoint alarms for the recorded measurements (channels), such as pH, level and power supply voltage.
Automatic Shutdown Multiple Bottle Mode: After complete revolution of distributor arm (unless Continuous Mode is selected)
Composite Mode: After preset number of samples have been delivered to composite container, from 1 to 999 samples, or upon full container.
Base Configuration Various (Compact, Standard & Large)
Base Type Various (Compact, Standard & Large)
Body material Impact resistant ABS plastic, 3-section construction Double-walled base with 2.54 cm insulation, direct ice contact with bottles (Sampler)
Bottle Set Various including Composite Bottles (2.5 gallon, 5.5 gallon, 4 gallon) or Discreet Bottles (24 x 1L, 24 x 575ml, 24 x 350ml 8 x 950ml)
Certifications CE, UL
Communication Capabilities USB and optional RS485 (Modbus)
Data logging SAMPLE HISTORY – Stores up to 4000 entries for sample time stamp, bottle number and sample status (success, bottle full, rinse error, user abort, distributor error, pump fault, purge fail, sample timeout, power fail and low main battery).
MEASUREMENTS – Stores up to 325,000 entries for selected measurement channels in accordance with the selected logging interval.
EVENTS – Ability to store up to 2000 entries in Sample History logging. Records Power On, Power Fail, Firmware Updated, Pump Fault, Distributor Arm Error, Low Memory Battery, Low Main Battery, User On, User Off, Program Started, Program Resumed, Program Halted, Program Completed, Grab Sample, Tube Change Required, Sensor Communication Errors, Cooling Failed, Heating Failed, Thermal Error Corrected.
Diagnostics View event and alarm logs as well as maintenance diagnostics
Dimensions Please contact your Hach sales representative for details.

Compact Base: 44.1 x 61 cm (17.4 x 24 in.)
Composite Base: 50.28 x 79.75 cm (19.8 x 31.4 in.)
NON-CONTACT LIQUID DETECT: Sample volume accuracy for applications that require complete tubing replacement
RAIN/RS485 PORT: Accepts Hach Rain Gauge (not included) or can be used as RS485 communications
Standard Base: 50.5 cm x 69.4 cm (19.9 x 27.3 in.)
TWO SENSOR PORTS: Accepts Hach digital Differential pH, Hach digital AV9000 analyzer with submerged area velocity flow and/or Hach digital US9000 ultrasonic level sensors
Display 1/4 VGA, Color; self-prompting/menu-driven program
Display Lock Function Access code protection prevents tampering
Housing Material PC/ABS blend, NEMA 4X, 6, IP68, corrosion and ice resistant (Controller)
Inputs One 0/4-20 mA input for flow pacing
Intake Strainers: Choice of PTFE and 316 stainless steel construction, or all 316 stainless steel in standard size, high velocity, and low profile for shallow depth applications
Purge: Air purged automatically before and after each sample;
duration automatically compensates for varying intake line lengths
Rinse: Intake line automatically rinsed with source liquid prior to each sample, from 1 to 3 rinses
Retries or Fault: Sample collection cycle automatically repeated from 1 to 3 times if sample not obtained on initial attempt
Internal Clock ±1 second per day at 25 °C (77 °F)
Languages
English, French, Spanish, Italian, German, Portuguese
Manual Sampling Initiates a sample collection independent of program in progress
Memory
Sample history: 4000 records;
Data log: 325,000 records;
Event log: 2000 records
Operating Mode Continuous or non-continuous
Power requirements (Voltage) 12V Battery (can be adapted to mains power)
Power supply Battery, 12V Lead acid, 3 pin
Probes included No
Programs
Dual Programs: Up to 2 sample programs can be run sequentially, in parallel, or according to day of week scheduling; enabling a single sampler to function like multiple samplers
Pump flow rate 4.8 L/min (1.25 gpm) at 1 m (3 ft) vertical lift with 3/8-in intake tube typical
Rain Gauge Enabled None
Sample Interval Selectable in single increments from 1 to 9,999 flow pulses or 1 to 9,999 mins in one minute increments
Sample Pump High-speed peristaltic, dual roller, with 0.95 ID x 1.6 OD cm (3/8 ID x 5/8 in. OD) pump tube
Sample Transport Velocity 2.9 ft/s (0.9 m/s) with 15 ft (4.6 m) vertical lift, 16 ft of 3/8-in. vinyl intake tubing, 70°F (21°C) and 5000 ft elevation
Sample Trigger When equipped with flow sensor or pH/temperature sensor or peripheral monitoring options, sampling can be triggered upon an upset condition when field selectable limits are exceeded
Sample Volume Programmable in 10 mL increments from 10 – 10,000 mL
Sample Volume Accuracy Typical: ±5% of 200 mL sample volume with: 4.6 m (15 ft) vertical lift, 4.9 m (16 ft) of 3/8- in. vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m (5000 ft) elevation
Sample Volume Repeatability Typical: ±5% of 200 mL sample volume with: 4.6 m (15 ft) vertical lift, 4.9 m (16 ft) of 3/8- in vinyl intake tube, single bottle, full bottle shut-off at room temperature and 1524 m (5000 ft) elevation
Sampling Mode
Pacing: Time Weighted, Flow Weighted, Time Table, Flow Table, Event
Distribution: Single bottle composite, multi-bottle composite, multi-bottle discrete, bottles per sample, samples per bottle or a combination of bottles per sample and samples per bottle
Sensor Ports 1
Sensors None
Status Messages Communicates what program is running, if there are any missed samples, when the next sample will be taken, how many samples remain, number of logged channels, time of last measurement, memory available, number of active channels, if alarms were triggered, when alarms were triggered, active sensors and cabinet temperature
Suction Hose Outer Diameter 1/4″ and 3/8″ ID PTFE-lined Polyethylene with protective outer cover available in clear and black.
Temperature Operating: 0 – 49 °C
-40 – 60 °C
Tubing Pump tubing: 9.5 mm ID x 15.9 mm OD Silicone

Intake tubing: 1.0 – 4.75 m minimum length, 1/4″ or 3/8″ ID Vinyl or 3/8″ ID PTFE-lined Polyethylene with protective outer cover (black or clear)

User Interface Membrane switch keypad with 2 multiple function soft keys
User Interface Languages Chinese, English, French, German, Italian, Spanish, Portuguese
Vertical Lift Maximum of 28 ft using 29 ft of 3/8-in. vinyl intake tube at sea level at 20-25°C (68-77°F)
Warranty 12 months
Weight Model dependent (~15kg)
What’s included?
Model dependent
Models
Various AS950 models are available depending on your requirements.
Please consult with Aqualab before ordering.

Available models include:

  • AS950 Portable Compact Sampler Bundle, 12V, with 2.5 Gallon Bottle
    Product number# ASP.CXXXC121XX
  • AS950 Portable Standard Sampler Bundle with 2.5 Gallon Bottle
    Product number# ASP.CXXXS121XX
  • AS950 Portable Standard Sampler Bundle with Two Sensor Ports, One Rain Port and 24- 1 liter Bottles
    Product number# ASP.CSRXS141XX
  • AS950 Portable Compact Sampler Bundle with Two Sensor Ports and 2.5 Gallon Bottle
    Product number# ASP.CSXXC121XX
  • AS950 Portable Standard Sampler Bundle with Two Sensor Ports and 2.5 Gallon Bottle
    Product number# ASP.CSXXS121XX
  • AS950 Portable Standard Sampler Bundle with Two Sensor Ports and 24- 1 liter Bottles
    Product number# ASP.CSXXS141XX
  • AS950 Portable Standard Sampler Bundle, 12V, with 24- 1 liter Bottles
    Product number# ASP.CXXXS141XX
Downloads
Manuals
AS950 Portable Sampler User Manual (Full)

AS950 Portable Sampler User Manual (Full)

Download now
AS950 Controller User Manual (Full)

AS950 Controller User Manual (Full)

Download now
Additional files
Pairing the Hach AS950 Automatic Sampler with Digital Flow Sensors

Pairing the Hach AS950 Automatic Sampler with Digital Flow Sensors

DOC043.53.30345.Apr16.pdf
Download now
AS950 Industrial Pre-Treatment Sampling

AS950 Industrial Pre-Treatment Sampling

DOC043.53.30460.Jul18-Industrial-Pre-treatment-Sampling.pdf
Download now
AS950 Technical Drawing

AS950 Technical Drawing

Download now
AS950 Mounting Bracket Instructions

AS950 Mounting Bracket Instructions

DOC276-99-80504_1ed-AV9000-Mounting-Bracket.pdf
Download now
Optional Accessories
  • AS950 Pump Tubing (4.5m)
    Product number# 4600-15
  • AS950 Pump Tubing (15m)
    Product number# 4600-50
  • AS950 Replacement Battery (12 Volt Lead Acid) with 3 pin connector
    Product number# 8754400
  • AS950 Battery Charger (230v) with 3 pin connector
    Product number# 875300AU
  • AS950 Composite Bottle (2.5 Gallon) Polyethylene With Cap
    Product number# 1918
  • AS950 Composite Bottle (5.5 Gallon) Polyethylene With Cap
    Product number# 6494
  • AS950 Discreet Bottle Set (24 x 1L) Polyethylene With Cap
    Product number# 737
  • AS950 Discreet Bottle Set (24 x 575ml) Polyethylene With Cap
    Product number# 1369
  • AS950 Intake Strainer (PTFE/Stainless Steel)
    Product number# 926
  • AS950 Intake Strainer (316 Stainless Steel) 1" x 8"
    Product number# 2070
Videos
  • Hach AS950 Sampler Flow Pacing Methods Pt. 1
  • Hach AS950 Sampler Flow Pacing Methods Pt. 1
Software
FSDATA Desktop English

FSDATA Desktop English

Software

Download now

Have A Question About This Product?