TU5200 Laboratory Laser Turbidimeter without RFID, ISO Version

The next standard in the evolution of turbidity

The next standard in the evolution of turbidity
The TU5 Series benchtop turbidimeters for drinking water and other pure water applications feature a revolutionary 360° x 90° Detection Technology, engineered to see more of your sample than any other turbidimeter. This unique technology is used in both the TU5 online and TU5 benchtop turbidimeters, allowing you for the first time to remove the uncertainty of which measurement to trust. The 360° x 90° Detection delivers the best low level precision and sensitivity while minimising variability from test to test. The TU5 Series benchtop turbidimeters are available in four different models with stable laser light source: two EPA and two ISO models, each with an additional RFID option that allows you to compare values from online and lab measurements.

FEATURES

Groundbreaking 360° x 90° Detection™ Technology

The TU5 Series employs a patented optical design that sees more of your sample than any other turbidimeter, delivering the best low level precision and sensitivity while minimizing variability from test to test.

Matching lab and online results

For the first time you will be able to remove the uncertainty of which measurement to trust, thanks to identical 360° x 90° Detection™ Technology in both instruments.

Everything about turbidity – faster

The TU5 Series dramatically reduces the time needed to get a turbidity measurement you can rely on, with 98% less online sample surface area to clean, sealed vials for calibration, and the elimination of the need for indexing and silicone oil in the lab. Not to mention, a smaller online sample volume means you will detect events almost immediately.

Specs
Accuracy
±2 % plus 0.01 NTU from 0 – 40 NTU;
±10 % of reading from 40 – 1000 NTU based on Formazin primary standard (at 25 °C)
Calibration Method For Formazin and Stablcal:
20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full rangeCustom calibration for up to 6-point calibrationsDegrees 0 – 100 mg/L
SDVB 0 – 1000 NTU
Certifications CE compliant
US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version
Complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
Australian ACMA Marking
Communication Link2sc
Dimensions (H x W x D) 195 mm x 409 mm x 278 mm
Display 7″ WVGA (800 x 480) colour TFT-LCD with touch screen
Enclosure Construction PC/ABS Blend Plastic
Light source Class 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
Model TU5200 ISO
Operating Humidity 80 % at 30 °C (non condensing)
Operating temperature range 10 – 40 °C
Power requirements (Hz) 50/60 Hz
Power requirements (Voltage) 100 – 240 VAC
Range EPA:
0 – 700 NTU / FNU / TE/F / FTU
0 – 100 mg/L
0 – 175 EBCISO:
0 – 1000 NTU / FNU / TE/F / FTU
0 – 100 mg/L
0 – 250 EBC
Regulatory DIN EN ISO 7027
Repeatability <40 NTU: Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater
>40 NTU: Better than 3.5% of reading on Formazin at 25 °C (77 °F)
Resolution 0.0001 NTU / FNU / TE/F / FTU / EBC / mg/L
Response time Signal averaging off: 7 seconds
Signal averaging on: 10 seconds (when averaging time is 5 seconds)
Sample Temperature 4 – 70 °C
Source Lamp: 850 nm Class 2 Laser
Storage conditions -30 – 60 °C
Stray Light <10 mNTU
Units NTU, FNU, TE/F, FTU, EBC;
mg/L if calibrated with Degrees calibration curve
Warranty 12 months
Weight 2.4 kg
What’s included?
TU5200 benchtop turbidimeter, user manual, Stablcal kit (10, 20 and 600 NTU), 2 sample vials, power supply, dust cover, vial stand