Water Quality

Hach

HACH ULTRATURB

Ultraturb sc Sensor

When connected to a Hach SC200 or Hach SC1000 controller/display, the Hach Ultraturb sc measures process turbidity within the range of 0.0001NTU – 1,000NTU.

Utilising a pulsed, long-life IR radiation LED, the Ultraturb sc is a low powered turbidimeter, manufactured in accordance with DIN EN ISO 7027 and permanently calibrated before leaving the factory.  Ultraturb sc units are ready for immediate use after connection to the Hach display/controller, and upon receiving a supply of sample water.

All optical and electronic assemblies are installed in housings that are physically very strong and proof against water jets.

FEATURES

Large measuring range: 0.0001 – 1,000 NTU

The Hach Ultraturb plus sc Sensor measures turbidity from 0 to 1000 FNU (NTU) for a wide variety of low to medium range turbidity applications. Use it to effectively monitor conventional filtered water processes, effluent water, distribution systems, and elevated tanks where small-sized particulates or air entrapment may be an issue.

Self-cleaning Sample Chamber Option

The Ultraturb sensor is available with an automatically self-cleaning sample chamber that guarantees stable measured values. The silicon wiper blades inside the sample chamber are held in place with a magnetic coupling wheel to further keep the sample chamber intact.

Suitable for seawater, brackish water, raw water and other applications

The new Ultraturb seawater sc is resistant to salt concentrations up to 65 g/L.

Ratio Methodology Detects Sample Chamber Fouling

The Ultraturb sensor uses ratio methodology with detection at 90° and 180° to minimize reflections in the measuring cell and on the windows. In this way, fouling of the sample chamber is detected earlier than with a single detection system.

Specs
Accuracy ± 0.008 FNU ±1% of reading whichever is greater
(0 – 10 FNU)
Automatic Wiper Yes
Cable Length 5 m
Calibration Method Stablcal or dry standard CVM module
Dimensions (H x W x D) 240 mm x 250 mm x 110 mm
Display Display provided through connection with Hach sc Controller
Inlet 13 mm ID Tubing or fixed connection (PVC system component pipework)
Material Housing: ASA; Window: Quartz; Wiper Blade: Silicon; Wiper Shaft: stainless steel 1.4571
Measurement method 90° infrared pulse scattered light technique in accordance with DIN EN ISO 7027
Model Ultraturb seawater
Operating temperature range 2 – 40 °C (36 – 104 °F)
Outlet 13 mm ID Tubing or fixed connection (PVC system component pipework)
Pressure Range 6 bar at 20 °C (87 psi at 68 °F)
Range 0.0001 – 1000 NTU (TE/F, NTU, FNU) can be programmed as required (0.001-250 EBC = 2500 ppm SiO2) (Note: 1 FNU is equivalent to 1 NTU)
Repeatability ± 0.003 FNU or ± 0.5% of reading (whichever is greater) from 0 – 2 FNU
Response time 1 – 60 s (programmable)
Sample Flow Rate 0.2 to 1 L/min
Sample Temperature Max. 50°C (122°F)
Sensor cleaning Wiper, automatic
Verification Stablcal or dry standard CVM module
Warranty 12 months
Weight Approx. 1.5 kg
What’s included? Hach Ultraturb sc, Factory Test Certificate, 4 wipers, Accessory set LZP816, User Manual.
Models
Various Ultraturb models are available depending on your requirements.
Please consult with Aqualab before ordering.

Available models include:

  • Ultraturb sc Sensor (5m cable)
    Product number# LPV415.99.22002
Downloads
Manuals
Ultraturb sc User Manual - AUS

Ultraturb sc User Manual - AUS

DOC023.53.03231_8ed.pdf
Download now
Additional files
Ultraturb sc Class 1 &  Class 2 Sensors

Ultraturb sc Class 1 & Class 2 Sensors

DOC023.97.80644_1ed.pdf
Download now
Ultraturb sc Introduction & Definition of Turbidity

Ultraturb sc Introduction & Definition of Turbidity

ex_turbidity.pdf
Download now
Ultraturb sc Measurement of Ballast Water

Ultraturb sc Measurement of Ballast Water

Hach-App-Note_BWM-Indicative-Measurement_F.pdf
Download now
Ultraturb sc Testing Ballast Water for  Invasive Species

Ultraturb sc Testing Ballast Water for Invasive Species

Hach-App-Note_Eliminate-Confusion-in-BW-Testing_F.pdf
Download now
Ultraturb sc Technical Drawing

Ultraturb sc Technical Drawing

LPV415_TD_00000__d1__001.pdf
Download now
Ultraturb sc CAD Files

Ultraturb sc CAD Files

UltraTurb-2D-and-3D-CAD-Files.zip
Download now
Optional Accessories
  • Ultraturb sc Desiccant 1
    Product number# LZX303
  • Ultraturb sc Desiccant 2
    Product number# LZX304
  • Ultraturb sc Replacement Wiper Blades (4 pack)
    Product number# LZV275
  • Ultraturb sc Calibration Syringe Set
    Product number# LZV451
  • Ultraturb sc Filter Set for Zero Point Calibration
    Product number# LZV325
  • Ultraturb sc Calibration/Verification Module (25 NTU)
    Product number# LZV414.00.40000
  • Ultraturb sc Calibration/Verification Module (1.5NTU)
    Product number# LZV414.00.10000
  • Ultraturb sc Calibration/Verification Module (6NTU)
    Product number# LZV414.00.20000
  • Ultraturb sc Calibration/Verification Module (0.6 NTU)
    Product number# LZV414.00.00000
  • Ultraturb sc Calibration/Verification Module (15 NTU)
    Product number# LZV414.00.30000
Software
Ultraturb sc Sensor Software Update

Ultraturb sc Sensor Software Update

Extract file to your PC. Carefully read instructions: sc sw upload instruction.pdf. Includes all available languages.

Download now
SC1000 Certified Multi-Sensor-DTM Software Package

SC1000 Certified Multi-Sensor-DTM Software Package

Zip file

Download now

Have A Question About This Product?