- User-set measurement and logging. Version -2 make separate measurements in 2 locations. The Bubbler managers pressure on each orifice line independently so that pressures in one line do not affect operation of the other line.
- Make measurements in separate channels or separate bodies of water or within the same area as redundant sensors (-2 version)
- Intall the Bubbler orifice with a vertical separation to get an extended range measurement of up to 50 psi total on a 25 psi unit.
- The -3 version adds a special ultra-accuate density sensor. The -3 density measurement is more accurate (0.1%) than measurements by separate stage sensors on-site would be.
- Bubbler is both a logger and a sensor, capable of working as a stand-alone or with other loggers/communcations devices via SDI-12, RS232 and RS485.
- Flash Log holds over 300,00 readings and allows recording of status, water level data.
- SDI-12 and RS232/RS485 interfaces provide data to loggers or communications equipment.
- Dual Orifice CF Bubbler supports MODBUS protocol.
- RS232 port supports a simple command line mode compatible with HyperTerminal and other communcations devices.
- RS232 port also provides full access to setup, status and Bubbler data plus easy connection to a modem or radio.
- Front panel for setting up operating parameters, monitoring performance, testing and examining the log.
- Self-contained needing only external power and orifice tubing.
- Long-life desiccant (1 year depending on local humidity and user set flow rate)
- User-set bubble rate for each line to accommodate a variety of field conditions.
- User-set configuration of single, dual orifice lices and extended range operation (-2 only)
- Built-in, precision Accubar® sensor, accuracy 0-20ft. 0.01 ft, 20-57.5ft. 0.05% reading. 50 psi version’s accuracy 20-115.3ft. 0.05% reading.
- User-configured averaging to filter out waves.
- User-set auto purge to keep the outlet clear of debris. Sensors auto zero after purge to prevent sensor drift.
- Redundant data storage when connected to an external logger.
- Home
- Sutron
- Dataloggers
- Dual Orifice Constant Flow Bubble Gage & Recorder
Dual Orifice Constant Flow Bubble Gage & Recorder
The Sutron Accubar® Constant Flow (CF) Dual Orifice Bubble Gauge/Recorder, a self-contained, precision device for measuring water levels, water temperature*, suspended sediment* & density* using long established bubble gauge principles, combines the following components into a single package. Ideal for rivers, streams, dams & reservoirs, oceans & industrial areas plus any area where water density changes, eg, tidal & estuary areas.