Water Quality

Hach

TL2300 High Range Benchtop Turbidimeter Series

The new TL2300 series laboratory turbidimeters blend trusted technology and improved features to simplify testing in the most demanding industrial and wastewater applications.

The TL2300 series large full color touch screen display and
intuitive user interface accelerate setup, calibration and
measurement. An easy interface and guided procedures give
you confidence in your results.

Various models are available:

EPA Models
TL2300 Turbidimeter (Tungsten Lamp, EPA):  0NTU – 4000NTU
TL2350 Turbidimeter (Tungsten Lamp, EPA):  0NTU – 10,000NTU

ISO Models
TL2310 Turbidimeter (LED Lamp, ISO):  0NTU – 1,000NTU
TL2360 Turbidimeter (LED Lamp, ISO):  0NTU – 10,000NTU

Please consult with Aqulab prior to purchasing.

 

 

 

FEATURES

Improved and intuitive design

The TL23 Series’ large full colour touch screen display and intuitive user interface accelerate setup, calibration and measurement. An easy interface and guided procedures give you confidence in your results.

A smart device for more reliable measurements

The TL23 Series ensures stable readings and accurate analysis by capturing turbidity readings once the device detects sample stability. This quality step removes subjectivity and the need for repeated measurements.

Easy to use. Easy to Be Right

The TL23 Series provides everything you need at your fingertips. With a USB port for easy data export, sample identification for traceability, and self-diagnostics for quality assurance, Hach® makes it easy to Be Right.

Specs
Accuracy Ratio on: ±2% of reading plus 0.01 NTU from 0 – 1000 NTU, ±5% of reading from 1000 – 4000 NTU based on formazin primary standard

Ratio off: ±2% of reading plus 0.01 NTU from 0 – 40 NTU

Air purge Dry nitrogen or instrument grade air (ANSI MC 11.1, 1975)
0.05 L/s at 69 kPa (10 psig); 138 kPa (20 psig) max
Hose barb connection for 1/8-inch tubing
Certifications CE, KC, RCM
Communication USB
Compliance EPA
Data logging 2000 total logs, includes reading log, verification log and calibration log
Dimensions (H x W x D) 153 mm x 395 mm x 305 mm
Display 17.8 mm colour touch screen
Interface 2 USB-A ports for USB flash drive, external thermal printer, keyboard and barcode scanner
Light source Tungsten filament lamp
Measurement method Nephelometric
Model TL2300 EPA
Operating temperature range 0 – 40 °C
Power requirements (Amps) 3.4 A
Power requirements (Hz) 50/60 Hz
Power requirements (Voltage) 100 – 240 VAC
Range
0 – 4000 NTU
NTU (Ratio on): 0 – 4000
NTU (Ratio off): 0 – 40
EBC (Ratio on): 0 – 980
EBC (Ratio off): 0 – 9.8
Reading modes Single, continuous, Rapidly Settling Turbidity, signal averaging on or off, ratio on or off
Regulatory Meets EPA Method 180.1
Repeatability ±1% of reading or 0.01 NTU, whichever is greater (under reference conditions)
Response time Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average)
Sample cell compatibility Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps
Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used
Sample requirements 25 mm sample cell: 20 mL minimum
0 to 70 °C (32 to 158 °F)
Source Lamp Tungsten Lamp
Stabilisation time Ratio on: 30 minutes after start-up
Ratio off: 60 minutes after start-up
Storage conditions -20 to 60 °C
Units NTU and EBC
Warranty 12 months
Weight 3.0 kg
What’s included? TL2300 Turbidimeter, silicone oil, oiling cloth, USEPA filter assembly, 1-inch sample cells (30 mL) with caps (6x), Gelex secondary turbidity standardization kit, Stablcal calibration kit, power supply, power cord, dust cover
Models
Various TL2300 models are available depending on your requirements.
Please consult with Aqualab before ordering.

Available models include:

  • TL2300 Tungsten Lamp Turbidimeter, EPA, 0 - 4000 NTU
    Product number# LPV444.99.00210
  • TL2350 Tungsten Lamp Turbidimeter, EPA, 0 - 10,000 NTU
    Product number# LPV444.99.00310
  • TL2310 LED Turbidimeter, ISO, 0 - 1000 NTU
    Product number# LPV444.99.00120
  • TL2360 LED Turbidimeter, ISO, 0 - 10,000 NTU
    Product number# LPV444.99.00320
Downloads
Additional files
TL2300 Turbidimeter 2100N / 2100AN Comparision

TL2300 Turbidimeter 2100N / 2100AN Comparision

DOC062.53.20265.pdf
Download now
TL2300 Turbidimeter Quick Guide for Food Applications

TL2300 Turbidimeter Quick Guide for Food Applications

DOC062.53.20231-1-1.pdf
Download now
TL2300 Turbidimeter Quick Guide for Chemical Applications

TL2300 Turbidimeter Quick Guide for Chemical Applications

DOC062.53.20232.pdf
Download now
TL2300 Turbidimeter Quick Guide Flow Cell Installation Guide

TL2300 Turbidimeter Quick Guide Flow Cell Installation Guide

DOC272.99.80547_1ed.pdf
Download now
Optional Accessories
  • TL2300 Turbidimeter Manual Flow Cell
    Product number# 9657100
  • TL2300 Turbidimeter Automated Flow Cell Kit
    Product number# 9658300
  • TL2300 Turbidimeter Sample Cell Oiling Cloth
    Product number# 4707600
  • TL2300 Turbidimeter Lamp Access Cover
    Product number# 9647700
  • TL2300 Turbidimeter Dust cover
    Product number# 9649100
  • TL2300 Turbidimeter Filter Assembly, USEPA Method 180.1
    Product number# 9653500
Software
TL23 Software Package

TL23 Software Package

Open the zip file and follow the instructions from the README file.

Download now