2100Q & 2100Qis Portable Turbidimeters

Perfect for both Field and Lab environments, the Hach 2100Q & 2100Qis are portable turbidity meters offering unsurpassed ease of use and accuracy in turbidity measurement.  The two-detector optical system compensates for color within the sample, light fluctuation, and stray light, enabling users to achieve laboratory-grade performance within field environments.

Calibration is made simple through the use of pre-sealed 20NTU, 100NTU, 800 NTU and 1000NTU calibration vials (#2464104).  Calibration verification is conducted using a 10NTU verification standard.

The Hach 2100Q & 2100Qis can be powered by either 4 x AA NiMH rechargeable batteries or 240v mains power.   Logged data (500 measurements) can be transferred to a PC (XML format) via USB cable.

Two Hach 2100Q model types are available:

2100Q:  0 – 1000 NTU
2100Qis:  0 – 1000 FNU

Please consult with Aqualab before ordering.

FEATURES

Easy calibration and verification

The Hach 2100Q Portable Turbidimeter provides confidence your measurements are right every time. On-screen assisted calibration and verification saves you time and ensures accuracy.
With an easy-to-follow interface, complicated manuals are not needed to perform routine calibrations. Single-standard RapidCal calibration offers a simplified solution for low level measurements.

Simple data transfer

Data transfer with the 2100Q is simple, flexible, and doesn’t require additional software. All data can be transferred to the included USB+Power Module and easily downloaded to your computer with a USB connection, providing superior data integrity and availability.

Accurate for rapidly settling samples

The HACH 2100Q Portable Turbidimeter incorporates an innovative Rapidly Settling TurbidityTM mode to provide accurate, repeatable measurements for difficult to measure, rapidly settling samples. An exclusive algorithm that calculates turbidity based on a series of automatic readings eliminates redundant measurements and estimating.

Convenient data logging

Up to 500 measurements are automatically stored in the instrument for easy access and backup. Stored information includes: date and time, operator ID, reading mode, sample ID, sample number, units, calibration time, calibration status, error messages, and the result.

Optical system for precision in the field

The two-detector optical system compensates for color in the sample, light fluctuation, and stray light, enabling analysts to achieve laboratory-grade performance on a wide range of samples, even under difficult site conditions.

Specs
Accuracy ± 2 % of reading plus stray light
Battery Requirements 4 x AA batteries
Certifications CE certified
Compliance Certifications CE/WEEE
Data logging 500 records
Dimensions (H x W x D) 77 mm x 107 mm x 229 mm
Display Size 240 x 160 pixels
Display Type Graphic LCD
Enclosure Rating IP67
Includes Model dependent (see below)
Interface USB
Light source 2100Q:  Tungsten filament lamp

2100Qis:  Light-emitting diode (LED)

Manual Languages English, French, German, Italian, Spanish, Portuguese (BR), Portuguese (PT), Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish
Max. operating humidity 90 %
Measurement method Ratio turbidimetric determination using a primary nephelometric light scatter signal (90°) and transmitted light scatter signal
Measurement Modes Normal (Push to Read), Signal Averaging, Rapidly Settling Turbidity
Operating temperature range 0 – 50 °C
Power Requirements 100 – 240 VAC, 50/60 Hz (with included USB+Power module)
Power Supply Batteries (see Battery Requirements)
Range 0 – 1000
Range 2 NTU or FNU (model dependent)
Reading modes Normal (Push to Read); Signal Averaging; Rapidly Setting Turbidity
Regulatory 2100Q :  EPA Method 180.1

2100Qis: Ratio turbidimetric determination using a primary nephelometric light scatter signal (90°) and transmitted light scatter signal.

Repeatability ± 1 % of reading or 0.01 NTU , whichever is greater
Response time 6 sec in normal reading mode
Sample Cell Compatibility 25 mm x 60 mm round
Sample requirements 15 mL (0.5 oz.)
Sample Volume 15 mL (0.5 oz.)
Signal Averaging Selectable on/off
Source Lamp 2100Q:  Tungsten filament lamp

2100Qis:  Light-emitting diode (LED)

Storage conditions -40 °C to 60 °C
Stray Light < 0.02 NTU
Units 2100Q:  NTU

2100Qis:  FNU

User Interface Button Graphic User Interface
User Interface Languages English, French, German, Italian, Spanish, Portuguese (BR), Portuguese (PT), Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish
Warranty 12 months
What’s included? 2100Q01USB:  Includes 2100Q instrument kit (2100Q01) and USB+Power Module (LZV813).

2100QIS01USB:  Includes 2100Q IS instrument kit (2100QIS01) and USB+Power Module (LZV813).

2100Q01-AU:  Includes  four AA alkaline batteries, a carrying case with insert, primary calibration standards in 1″ sealed vials (20, 100, 800 NTU), 10 NTU primary verification standard, 6 sample cells with screw-tops, instrument manual (printed and CD-ROM), quick start guide, silicone oil and oiling cloth.

2100QIS01USB:  Includes 2100Q IS instrument kit (2100QIS01) and USB+Power Module (LZV813).

 

Models
Various 2100Q models are available depending on your requirements.
Please consult with Aqualab before ordering.

Available models include:

  • 2100Q Portable Turbidimeter Kit with USB and Power Module (0 - 1000NTU)
    Product number# 2100Q01USB
  • 2100Q IS with USB+Power Module (0 - 1000 FNU)
    Product number# 2100QIS01USB
  • 2100Q Portable Turbidimeter (0 - 1000 NTU)
    Product number# 2100Q01-AU
  • 2100Q IS Portable Turbidimeter (0 - 1000 FNU)
    Product number# 2100QIS01-AU
Downloads
Manuals
2100Q User Manual

2100Q User Manual

DOC022.97.80041_5ed.pdf
Download now
Additional files
2100Q Quick Start Guide

2100Q Quick Start Guide

2100Q-and-2100Qis-Quick-Start-Guide.pdf
Download now
2100Q Water Analysis Guide (2013)

2100Q Water Analysis Guide (2013)

DOC316.53.01336_1ed-1.pdf
Download now
2100Q Determining Haze in Beer

2100Q Determining Haze in Beer

DOC042.53.20248.pdf
Download now
2100Q Calibration Methods for Low Level Turbidity Measurement

2100Q Calibration Methods for Low Level Turbidity Measurement

L2109.pdf
Download now
2100Q Power Module

2100Q Power Module

DOC272.97.80041_2ed.pdf
Download now
2100Q Measuring Turbidity in Power Plants

2100Q Measuring Turbidity in Power Plants

Turbidity-in-Power-App-Note_060.53.10120.Mar17.pdf
Download now
2100Q Coagulation, Flocculation and Clarification of Drinking Water

2100Q Coagulation, Flocculation and Clarification of Drinking Water

L2141.pdf
Download now
Optional Accessories
  • 2100Q Replacement Lamp Assembly
    Product number# 4653900
  • 2100Q Replacement Sample Cells with caps (10 mL / 6 pcs)
    Product number# 2434706
  • 2100Q Secondary Turbidity Standards Kit
    Product number# 2464105
  • 2100Q Sample Filtration & Degassing Kit
    Product number# 4397510
  • 2100Q Sample Degassing Kit