2100Q & 2100Qis Portable Turbidimeters
Perfect for both Field and Lab environments, the Hach 2100Q & 2100Qis are portable turbidity meters offering unsurpassed ease of use and accuracy in turbidity measurement. The two-detector optical system compensates for color within the sample, light fluctuation, and stray light, enabling users to achieve laboratory-grade performance within field environments.
Calibration is made simple through the use of pre-sealed 20NTU, 100NTU, 800 NTU and 1000NTU calibration vials (#2464104). Calibration verification is conducted using a 10NTU verification standard.
The Hach 2100Q & 2100Qis can be powered by either 4 x AA NiMH rechargeable batteries or 240v mains power. Logged data (500 measurements) can be transferred to a PC (XML format) via USB cable.
Two Hach 2100Q model types are available:
2100Q: 0 – 1000 NTU
2100Qis: 0 – 1000 FNU
Please consult with Aqualab before ordering.
- FEATURES
-
Easy calibration and verification
The Hach 2100Q Portable Turbidimeter provides confidence your measurements are right every time. On-screen assisted calibration and verification saves you time and ensures accuracy.
With an easy-to-follow interface, complicated manuals are not needed to perform routine calibrations. Single-standard RapidCal calibration offers a simplified solution for low level measurements.Simple data transfer
Data transfer with the 2100Q is simple, flexible, and doesn’t require additional software. All data can be transferred to the included USB+Power Module and easily downloaded to your computer with a USB connection, providing superior data integrity and availability.
Accurate for rapidly settling samples
The HACH 2100Q Portable Turbidimeter incorporates an innovative Rapidly Settling TurbidityTM mode to provide accurate, repeatable measurements for difficult to measure, rapidly settling samples. An exclusive algorithm that calculates turbidity based on a series of automatic readings eliminates redundant measurements and estimating.
Convenient data logging
Up to 500 measurements are automatically stored in the instrument for easy access and backup. Stored information includes: date and time, operator ID, reading mode, sample ID, sample number, units, calibration time, calibration status, error messages, and the result.
Optical system for precision in the field
The two-detector optical system compensates for color in the sample, light fluctuation, and stray light, enabling analysts to achieve laboratory-grade performance on a wide range of samples, even under difficult site conditions.
- Specs
-
Accuracy ± 2 % of reading plus stray light Battery Requirements 4 x AA batteries Certifications CE certified Compliance Certifications CE/WEEE Data logging 500 records Dimensions (H x W x D) 77 mm x 107 mm x 229 mm Display Size 240 x 160 pixels Display Type Graphic LCD Enclosure Rating IP67 Includes Model dependent (see below) Interface USB Light source 2100Q: Tungsten filament lamp 2100Qis: Light-emitting diode (LED)
Manual Languages English, French, German, Italian, Spanish, Portuguese (BR), Portuguese (PT), Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish Max. operating humidity 90 % Measurement method Ratio turbidimetric determination using a primary nephelometric light scatter signal (90°) and transmitted light scatter signal Measurement Modes Normal (Push to Read), Signal Averaging, Rapidly Settling Turbidity Operating temperature range 0 – 50 °C Power Requirements 100 – 240 VAC, 50/60 Hz (with included USB+Power module) Power Supply Batteries (see Battery Requirements) Range 0 – 1000 Range 2 NTU or FNU (model dependent) Reading modes Normal (Push to Read); Signal Averaging; Rapidly Setting Turbidity Regulatory 2100Q : EPA Method 180.1 2100Qis: Ratio turbidimetric determination using a primary nephelometric light scatter signal (90°) and transmitted light scatter signal.
Repeatability ± 1 % of reading or 0.01 NTU , whichever is greater Response time 6 sec in normal reading mode Sample Cell Compatibility 25 mm x 60 mm round Sample requirements 15 mL (0.5 oz.) Sample Volume 15 mL (0.5 oz.) Signal Averaging Selectable on/off Source Lamp 2100Q: Tungsten filament lamp 2100Qis: Light-emitting diode (LED)
Storage conditions -40 °C to 60 °C Stray Light < 0.02 NTU Units 2100Q: NTU 2100Qis: FNU
User Interface Button Graphic User Interface User Interface Languages English, French, German, Italian, Spanish, Portuguese (BR), Portuguese (PT), Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish Warranty 12 months What’s included? 2100Q01USB: Includes 2100Q instrument kit (2100Q01) and USB+Power Module (LZV813). 2100QIS01USB: Includes 2100Q IS instrument kit (2100QIS01) and USB+Power Module (LZV813).
2100Q01-AU: Includes four AA alkaline batteries, a carrying case with insert, primary calibration standards in 1″ sealed vials (20, 100, 800 NTU), 10 NTU primary verification standard, 6 sample cells with screw-tops, instrument manual (printed and CD-ROM), quick start guide, silicone oil and oiling cloth.
2100QIS01USB: Includes 2100Q IS instrument kit (2100QIS01) and USB+Power Module (LZV813).
- Models
-
Various 2100Q models are available depending on your requirements.
Please consult with Aqualab before ordering.Available models include:
-
2100Q Portable Turbidimeter Kit with USB and Power Module (0 - 1000NTU)
Product number# 2100Q01USB -
2100Q IS with USB+Power Module (0 - 1000 FNU)
Product number# 2100QIS01USB -
2100Q Portable Turbidimeter (0 - 1000 NTU)
Product number# 2100Q01-AU -
2100Q IS Portable Turbidimeter (0 - 1000 FNU)
Product number# 2100QIS01-AU
-
2100Q Portable Turbidimeter Kit with USB and Power Module (0 - 1000NTU)
- Downloads
-
Manuals 2100Q User Manual
DOC022.97.80041_5ed.pdfDownload now Additional files 2100Q Quick Start Guide
2100Q-and-2100Qis-Quick-Start-Guide.pdfDownload now 2100Q Water Analysis Guide (2013)
DOC316.53.01336_1ed-1.pdfDownload now 2100Q Determining Haze in Beer
DOC042.53.20248.pdfDownload now 2100Q Calibration Methods for Low Level Turbidity Measurement
L2109.pdfDownload now 2100Q Power Module
DOC272.97.80041_2ed.pdfDownload now 2100Q Measuring Turbidity in Power Plants
Turbidity-in-Power-App-Note_060.53.10120.Mar17.pdfDownload now 2100Q Coagulation, Flocculation and Clarification of Drinking Water
L2141.pdfDownload now - Optional Accessories
-
-
2100Q Replacement Lamp Assembly
Product number# 4653900 -
2100Q Replacement Sample Cells with caps (10 mL / 6 pcs)
Product number# 2434706 -
2100Q Secondary Turbidity Standards Kit
Product number# 2464105 -
2100Q Sample Filtration & Degassing Kit
Product number# 4397510 -
2100Q Sample Degassing Kit
Product number# 4397500 -
2100Q Replacement NiMH Batteries (4 x AA)
Product number# 2971304 -
2100Q USB Barcode Scanner
Product number# LZV566
-
2100Q Replacement Lamp Assembly
- Videos
-
-
2100Q Portable Turbidimeter, Setup & Operation - High-Level Measurement
-
Hach 2100Q Portable Water Tester
-